FUJIFILM Life Science
Products
BulletLAS-4000
Features
Imaging Samples
System Spec
BulletLAS-4000mini
BulletFLA-5100
BulletFLA-7000
BulletFLA-9000
BulletBAS-5000
BulletAP-3000
BulletImaging Plates
BulletAccessories
BulletMore Products
BulletReagents
LAS-4000

Image Capturing Unit (Requires Additional Analyzing Unit)


CCD chip: Fujifilm Super CCD Area Type chip (15.6 x 23.4mm)
Number of Pixels: 3.2 million pixels
Pixel Size: Aprrox. 11mm
Cooling: Two stage thermoelectric module with air circulation
Cooling Temperature: Down to -30°C (when the room temperature is below 28°C)
Focusing: Automatic, remote operation
Exposure Mode: Automatic / Manual (normal / incremental / repetitive / program / in vivo)
Exposure Time: Automatic / Manual (1/100 Seconds to 30 Hours)
Pixel Correction: Dark-frame correction, flat-frame correction, distortion correction, etc.
Image Quality Correction: Binning and Smoothing
Image Size: Up to 12 MB (formatsL FUJI and TIFF)
Read Pixel Size: Down to 35 µm
Maximum Sample Size: 21x14 cm (25 x 25 cm when using a wide-view lens)
Interface: USB2.0


Intellignet Dark Box Set

Includes; IDX box, Epi-tray, USB Cable

Lens

Includes; IDX box, Epi-tray, USB Cable

High-sensitivity lens FUJINON Lens VRF43LMD 3
Sigma Wide-view Lens is also available

Operating Conditions

Line Frequency 50 - 60 Hz
Temperature 15 - 28°C
Humidity 30 - 70% (no condensation)
Supply Voltage 100 - 240V
Power Consumption Approx. 0.3 kVA

Dimensions

Camera Head and Dark Box 510 (W) x 900 (H) x 480 (D) mm

Optional Products*

UV 2020 Transilluminator set
Includes; UV Transilluminator(312nm), Gel sheet, UV Dia-tray, 605DF40 filter

White Transilluminator(470~740nm) set
Includes; White Trans-illuminator, White Dia-tray

Epi-Blue Illuminator set
Includes; Epi-Blue(460nm) / White Illuminator, Y515 filter

Epi-Green Illuminator set
Includes; Epi-Green(520nm) / White Illuminator, 575DF20 filter

Epi-Red Illuminator set
Includes; Epi-Red(630nm) / White Illuminator, R670 filter

Epi-IR Illuminator set
Includes; Epi-IR(710nm) / White Illuminator, IR785 filter

Epi-UV Illuminator set
Includes; Epi-UV(365nm) / White Illuminator, L41 filter

UV Dia-tray set
Includes; UV Dia-tray, Gel sheet

Non-parallax tray

Optical Filter: Y515
510DF10 for GFP detection
605DF40 for EtBr detection

Filter changer

*Each light source set includes filter(s) for the corresponding wavelength range(s).
The three optional filters can be purchased individually.

Analyzing Unit

Computer
OS Mac® OS X 10.4.4 or later
Windows® XP Pro SP2

Analysis software
ScienceLab (MultiGauge)

Applicable Reagents and/or Samples

Luminescence
ECL™, ECL Plus™, ECL Advance™, Lumi-Light Plus, SuperSignal®, CDP-Star®, CSPD®, Immobilon, Bright-Star™

Fluorescence/IR
DY676, DY781, Alexa Flour®680, Alexa Flour®700

Fluorescence/red
Alexa Flour®633, Alexa Flour®635, Alexa Flour®647, Cy™5, BODIPY®650/665, DiD, TOTO®-3, DDAO phosphate

Fluorescence/green
SYPRO®Red, Cy™3, TAMRA™, ROX™, HEX™, Alexa Fluor®532, Alexa Fluor®546, Deep Purple, Pro-Q® Diamond, Rhodamine Red™, BODIPY®576/589, NED™, R-phycoerythrin, RFP, HNPP, Tetramethylrhodamine

Fluorescence/blue
SYBR® Green I, SYBR® Green II, SYBR® Gold, SYPRO® Ruby, SYPRO® Orange, SYPRO® Tangerine, FITC, FAM™, EGFP, ECFP, AttoPhos™

Fluorescence/epi-UV
Ethidium Bromide, SYPRO® Rose, Qdot®

Fluorescence/trans-UV
Ethidium Bromide

Digitizing/white epi-illumination/white transillumination
Silver staining, CBB, NBT/BCIP, X-ray film, etc.

*The reagents listed above are representative reagents with high performance results. Please contact us for other reagents.

Specs

 
Bottom Nav