Super CCD Chip Affords Up To 6.3 Million Pixels
 |
| Super CCD chip |
 |
| Octagonal pixel-interwoven layout |
By rotating pixels 45 degrees to form an interwoven layout, the Super CCD's pixel pitch in the horizontal and vertical directions is narrower than in the diagonal direction, achieving higher horizontal and vertical resolution. |
Equipped with a Newly Designed Large-Aperture F0.85 Lens
The analyzer incorporates a FUJINON, a strikingly bright lens with an F-number of 0.85. This lens has been especially designed to make full use of the advantages of Fujifilm's proprietary Super CCD chip, and is excellent for capturing images from distances as short as several tens of centimeters. In its design, optical expertise developed through professional applications such as broadcasting TV camera lens is fully exploited. |
|
 |
| FUJINON lens VRF43LMD 3 F0.85 |
|
High Performance in a Compact Body
The same grade of camera and lens as in LAS-4000, the highest-grade model of the LAS series, are used. A compact body is made possible while still retaining the high resolution and high performance of LAS-4000. Free from the necessity for dark rooms and chemicals, the analyzer can be placed on the top or side of an ordinary desk, and requires no special expertise for operation.
Image Capture Software "LAS-4000mini Image Reader"
The self-explanatory and user-friendly software allows specification of all image capture parameters, including sensitivity, resolution and image methods. The software automatically carries out all image correction functions. In increment mode, the signal increase is shown in real time, by capturing and automatically displaying up to 16 images. With this software users can create their own settings and methods. A photograph of the sample can be made and overlaid with the signal image.
Optional Products
UV 2020 transilluminator set
Includes; UV 2020 transilluminator, 605DF40 optical filer for EtBr detection, UV-Dia tray, Gel sheet, etc.
UV-Bay set
Includes; Housing box for UV transilluminator, Filter frame, Filter housing, Bottom shield
EPI Blue Illuminator
Includes; EPI Blue / White Illuminator, Y515 optical filter, etc.
*The product with EPI Blue illuminator is categorized as the class 1 laser (LED) (IEC60825-1+A2:2001)
Optical Filter
510DF10 for GFP detection
Optical Filter
605DF40 for EtBr detection
Optical Filter
Y515 |
 |
| NP Tray |
Non-parallax (NP) tray
A non-parallax (NP) tray is used to eliminate the parallax
effect when imaging chemiluminescence in the 96-well plate.
Up to two plates can be placed.
|
|